New and used test
equipment rental and sales including: oscilloscopes network
analyzers spectrum analyzers and other electronic testing
equipment from: Tektronix Agilent Fluke QuadTech, Rohde
and Schwarz among other respected tested manufacturers.
|
New! Tektronix TDR and Electrical Sampling Modules:
Models Available: 80E01, 80E02, 80E03, 80E04, 80E06, 80E07, 80E08, 80E09, 8E010 |
All modules have independent incident
step and receiver deskew to remove the
effect of measurement fixtures and probes
that enable faster and easier de-embedding
of test fixtures.
When the user employs these modules
with Tektronix IConnect® TDR and VNA
software, he or she can acquire up to
1,000,000 data points and obtain up
to 50 GHz differential, mixed-mode and
single-ended S-parameters. IConnct
also enables impedance, S-parameters
and eye diagram compliance testing as
required by various serial data standards,
as well as full channel nalysis,Touchstone
(SnP) file output and SPICE modeling for
gigabit interconnects. |
|
For S- Parameter and TDR Testing - See All Modules |
|
|
|
Features and Benefits: |
All Modules:
- Up to 70 GHz Bandwidth and 5 ps Measured Rise Time (10 - 90%)
- Lowest Noise for Analysis – 450 μVRMS at 60 GHz, 300 μVRMS at 30 GHz
- Remote Samplers*1 Enable Location of Sampler Near DUT and Ensure Best Signal Fidelity
- Independent Sampler Deskew Ensures Easy Fixture and Probe De-embedding
- Dual Channel (Except 80E01 and 80E06)
- Precision Microwave Connectors (3.5 mm, 2.92 mm, 2.4 mm and 1.85 mm)
- Probe Support (Except 80E06)
TDR Modules:
- 15 ps Reflected True Differential Fully Integrated TDR Rise Time (12 ps Incident) and Feature Resolution Below 1 mm
- Efficient, Accurate, Easy to use, and Cost Effective S-parameters up to 50 GHz
|
Key Performance Specifications: |
TDR Modules |
Variable Bandwidth |
CH |
Step Reflected Rise Time |
RMS Noise |
Dynamic Range |
Remote sampler |
80E10 |
50 GHz |
2 |
15 ps |
≤600µVRMS |
1.0 Vp-p |
Yes |
40 GHz |
- |
≤370µVRMS |
30 GHz |
- |
≤300µVRMS |
80E08 |
30 GHz
|
2 |
22 ps
|
≤300µVRMS |
1.0 Vp-p |
Yes |
20 GHz |
- |
≤280µVRMS |
80E04 |
20 GHz |
2 |
35ps |
≤600µVRMS |
1.0 Vp-p |
Extender cable, accessory |
|
Electrical Modules |
Varaible Bandwidth |
CH |
Acquisition Rise Time (10% - 90-%) |
RMS Noise |
Dynamic Range |
Remote Sampler |
80E09 |
60 GHz
|
2 |
5.8 ps
|
450µVRMS
|
1.0 Vp-p |
Yes |
40 GHz |
- |
330µVRMS |
30 GHz |
- |
300µVRMS |
80E07 |
30 GHz
|
2 |
11.7 ps
|
300µVRMS |
1.0 Vp-p |
Yes |
20 GHz |
- |
280µVRMS |
80E03 |
20 GHz |
2 |
17.5 ps |
≤600µVRMS |
1.0 Vp-p |
Extender cable, accessory |
|
Applications: |
- Impedance Characterization and S-parameter Measurements for Serial Data Applications
- Advanced Jitter, Noise and BER Analysis
- Channel and Eye Diagram Simulation and Measurement-based Spice Modeling
80E10, 80E08, and 80E04
- High-Performance TDR/T Measurements
- Impedance Profile, Inductance, Capacitance and S-parameters
- Transmission Line Quality, Impedance, and Crosstalk
- True Differential, Common Mode, and Single Ended Measurements
- Efficient Fault Isolation
80E09, 80E07, 80E06, 80E01
- High-Frequency, Low-Noise Signal Acquisition
- Fast Rise Time Measurements
- Jitter Analysis and Waveform Analysis
80E03 and 80E02
- Device Characterization, Transmission Quality, Waveform Parameters
- Low Signal Measurements
*1 Integrated on 80E07 – 80E10 and optional on 80E01 – 80E04 and 80E06.
|
| Model# |
Description |
Includes |
To request a free quote |
| 80E10 |
Dual Channel, 50 GHz True Differential TDR Sampling Module with Remote Samplers |
User manual, certificate of traceable calibration standard, two precision adapters to 2.92 mm included with 50 Ω SMA terminations. |
 |
| 80E09 |
Dual Channel, 60 GHz Sampling Module. |
 |
| 80E08 |
Dual Channel, 30 GHz True Differential TDR Sampling Module with Remote Samplers |
User manual, certificate of traceable calibration standard, two 50 Ω SMA terminations. |
 |
| 80E07 |
Dual Channel, 30 GHz Sampling Module. |
 |
| 80E06 |
70+ GHz Electrical Sampling Module. |
User manual, calibration data report, precision adapter to 2.92 mm with 50 Ω SMA termination. |
 |
| 80E06X2 |
Bundled ordering configuration provides two 80E06 modules. |
| 80E04 |
Dual Channel, 20 GHz True Differential TDR Sampling Module |
User manual, calibration data report, two 50 Ω SMA terminations. |
 |
| 80E03 |
Dual Channel, 20 GHz Sampling Module. |
 |
| 80E02 |
Dual Channel, 12.5 GHz Sampling Module. |
 |
| 80E01 |
Single Channel, 50 GHz Sampling Module. |
User manual, calibration data report, precision adapter to 2.92 mm included with 50 Ω SMA termination. |
 |
|
|
|