New and used
test equipment
rental and sales including:
oscilloscopes
network analyzers
spectrum analyzers
and other electronic
testing equipment from:
Tektronix
Agilent
Fluke
QuadTech,
Rohde and Schwarz
among other respected
tested manufacturers.
Search Results:
The equipment below may be available new or used, for rental, sale or lease.
Agilent (HP) E4411A Spectrum Analyzer, 9kHz-1.5GHz
Frequency range 9 kHz to 1.5 GHz with frequency accuracy of ±2.0 kHz at
1 GHz. Phase noise <= -90 dBc/Hz (10 kHz offset) and residual FM <=100 Hz P-P. Resolution bandwidths 1 kHz to 3 MHz. Maximum amplitude range -120 dBm to +30 dBm. Maximum dynamic range >=78 dB/>=85 dB (2nd/3rd order). Log range 85 dB with 10 divisions on screen.
15.8 cm, high resolution, LCD display, continuous background environment
alignment.
Agilent E8267D PSG Vector Signal Generator, up to 44GHz
Agilent's E8267D PSG vector signal generator is the industry's first integrated microwave vector signal generator with I/Q modulation up to 44 GHz. It features an advanced wideband internal baseband generator capable of flexible arbitrary waveform playback or sophisticated real-time signal generation. The E8267D PSG also has a built-in wideband I/Q modulator that delivers up to 2 GHz RF modulation bandwidth and is a perfect complement to Agilent's N6030A stand-alone wideband arbitrary waveform generator for I/Q waveform simulations up to 1 GHz RF bandwidth. This groundbreaking integrated vector functionality, only available in the E8267D PSG, drastically simplifies the generation of complex modulated signals for design and manufacturing test applications in aerospace, defense, satellite communications, and broadband wireless.
Associated Research 6554SA Electrical Safety Compliance Analyzer
Output voltage: 5kV AC and DC; Output current : 40mA (AC) and 40mA (DC); Insulation resistance voltage range: 200-1000V; resistance range: 0-999mO; Ground bond test range: 5-12V AC; Output current: 10-31A.
Fluke FLUKE-1621 EARTH GROUND TESTER
Fluke FLUKE-1623 KIT BASIC GEO EARTH GROUND TESTER
Fluke FLUKE-1623 BASIC GEO EARTH GROUND TESTER
Fluke FLUKE-1625 KIT ADVANCED GEO EARTH GROUND TESTER
Fluke FLUKE-1625 ADVANCED GEO EARTH GROUND TESTER
Fluke FLUKE-1630 EARTH GROUND CLAMP
Fluke GEO CABLE-REEL 25M A604505102, GROUND/EARTH CABLE REEL 25M WIRE
Fluke GEO CABLE-REEL 50M A604505103, GROUND/EARTH CABLE REEL 50M WIRE
Fluke GEO EARTH STAKE A604510350, GROUND/EARTH EARTH STAKE
QuadTech 1868A Megohmmeter
Measurement Range: 10k? to 1P?.
Basic Accuracy: ± 2% to 1T? .
Programmable Test Voltage: 10V to 1kV (1868A), 50V to 5kV (1868D) .
Selectable Charge Current: to 80mA (1868A), to 18mA (1868D).
Leakage Current Measurement Down to 1pA (± 2% Basic Accuracy).
Programmable Charge, Delay and Discharge Times.
5 Programmable Limit Sets.
Internal Storage of 4 Tests (20 Steps each) Plus Additional Storage with Optional PCMCIA Memory Card.
Standard RS232, IEEE and Remote I/O Interfaces.
Graphic LCD with Text, Bar Graph and X-Y Graph Displays.
Current or Resistance Display Mode.
4 Ranges Plus Automatic Ranging.
Automatic Zeroing.
Contact Check Function.
Floating Power Supply (1868A) for Measurements on Grounded Devices.
QuadTech 1868D Megohmmeter
Measurement Range: 10k? to 1P?.
Basic Accuracy: ± 2% to 1T?.
Programmable Test Voltage: 10V to 1kV (1868A), 50V to 5kV (1868D).
Selectable Charge Current: to 80mA (1868A), to 18mA 1868D).
Leakage Current Measurement Down to 1pA (± 2% Basic Accuracy).
Programmable Charge, Delay and Discharge Times.
5 Programmable Limit Sets.
Internal Storage of 4 Tests (20 Steps each) Plus Additional Storage with Optional PCMCIA Memory Card.
Standard RS232, IEEE and Remote I/O Interfaces.
Graphic LCD with Text, Bar Graph and X-Y Graph Displays.
Current or Resistance Display Mode.
4 Ranges Plus Automatic Ranging.
Automatic Zeroing.
Contact Check Function.
Floating Power Supply (1868A) for Measurements on Grounded Devices.
QuadTech Guardian1010/1050 AC Hipot Tester/Groundbond Tester (CE, TUV)
AC Output Voltage: Range: 50V to 5000V AC.
Resolution: 1Volts/step.
Frequency: 50/60 Hz selectable.
AC Current Display: Total and Real Current.
Range: 0.001mA to 30mA AC.
Includes:
G13 - Corded Product Adapter (115V).
S12 - Load Box, resistive.
S15 - Interconnection Cable to S50.
G36 - RS232 Interface, 1050.
QuadTech Guardian1030/1050 AC Hipot Tester/Groundbond Tester (CE, TUV)
AC Output Voltage: Range: 50V to 5000V AC.
Resolution: 1Volts/step.
Frequency: 50/60 Hz selectable.
AC Current Display: Total and Real Current.
Range: 0.001mA to 30mA AC.
DC Output Voltage: Range: 50V to 6000V DC.
Resolution: 1Volts/step.
DC Current Display: Range: 0.0001mA to 10mA DC.
3 Ranges: .0001mA - 0.3mA,
0.31mA - 3mA, 3.1mA - 10mA.
Insulation Resistance: Range: 0.1MO - 50GO.
1M - 1G: +/- (5% + 10 cts), >500V.1G - 10G: +/- (10% + 10 cts), >500V.
10G - 50G: +/- (15% + 10 cts), >500V..1M - 1G: +/- (10% + 10 cts), <500V.
Includes:
G13 - Corded Product Adapter (115V).S12 - Load Box, resistive.
S15 - Interconnection Cable to S50.
G36 - RS232 Interface, 1050.
QuadTech Guardian1050 Ground Bond Tester
Programmable Output Current to 45A AC.
RS-232, IEEE, Printer options.
Four - Terminal Resistance measurements to 510mOhms.
99 Programmable steps/ 99 Memory locations.
Programmable Source Voltage 1 - 8V.
QuadTech Guardian2510 AC Hipot Tester (UL)
Programmable Output Voltage to 5kV AC.
Measurement of Real, Imaginary and Total Current.
Ground Fault Interruption (GFI) for operator safety.
Programmable Ramp, Test and Fall Times.
Storage of Tests Setups, 25 User (5 predefined), and 9 Multi-step with 3 steps per measurement.
Continuous Leakage Current.
Monitoring down to 0.1µA.
Ground Continuity Test with Adjustable Limits.
Password Protected Front Panel Lockout.
Remote I/O, RS-232 Interface standard, IEEE-488, and Enhanced Remote Optional.
Review of Data after Measurement.
Insulation Resistance Measurements from 10kW to 2TW.
QuadTech Guardian2520 AC/DC Hipot Tester (UL)
Programmable Output Voltage to 5kV AC and 6kV DC.
Measurement of Real, Imaginary and Total Current.
Ground Fault Interruption (GFI) for operator safety.
Programmable Ramp, Test and Fall Times.
Storage of Tests Setups, 25 User (5 predefined), and 9 Multi-step with 3 steps per measurement.
Continuous Leakage Current.
Monitoring down to 0.1µA.
Ground Continuity Test with Adjustable Limits.
Password Protected Front Panel Lockout.
Remote I/O, RS-232 Interface standard, IEEE-488, and Enhanced Remote Optional.
Review of Data after Measurement.
QuadTech Guardian2530 AC/DC/IR Hipot Tester (UL)
Programmable Output Voltage to 5kV AC and 6kV DC.
Measurement of Real, Imaginary and Total Current.
Ground Fault Interruption (GFI) for operator safety.
Programmable Ramp, Test and Fall Times.
Storage of Tests Setups, 25 User (5 predefined), and 9 Multi-step with 3 steps per measurement.
Continuous Leakage Current.
Monitoring down to 0.1µA.
Ground Continuity Test with Adjustable Limits.
Password Protected Front Panel Lockout.
Remote I/O, RS-232 Interface standard, IEEE-488, and Enhanced Remote Optional.
Review of Data after Measurement.
Insulation Resistance Measurements.
from 10kO to 2TO.
QuadTech Guardian6000 Electrical Safety Analyzer
Programmable output voltage to 5kV AC and 6kV DC.
Ground Bond Testing to 30A AC with Adjustable Limit.
Programmable Ramp and Test Times.
Storage of 50 Tests Setups with 10 Steps per Setup.
Continuous Leakage Current Monitoring.
Trip Current Programmable to 40mA AC and 20mA DC.
Front Panel Lockout via Password.
Standard IEEE and Remote Control Interfaces.
Optional RS232 Interface.
Insulation Resistance Measurements from 100kO to 50GO.
QuadTech Guardian6100-01 Safety Analyzer w/G31 (500VA)
Programmable output voltage to 5kV AC and 6kV DC.
Adds G31 Isolation Transformer (500VA).
Ground Bond Testing to 30A AC with Adjustable Limit.
Line Leakage Current Measurement (Earth, Patient and Enclosure) with 5 Human Body Models.
Monitoring of DUT Current Draw.
Programmable Ramp and Test Times.
Storage of 99 Tests Setups with 99 Steps per Setup.
Continuous Leakage Current Monitoring.
Trip Current Programmable to 40mA AC and 20mA DC.
Front Panel Lockout via Password.
Standard IEEE and Remote Control Interfaces.
Optional RS232 Interface.
Insulation Resistance Measurements from 100kO to 50GO.
QuadTech Guardian6100-02 Safety Analyzer w/G32 (1000VA)
Programmable output voltage to 5kV AC and 6kV DC.
Adds G32 Isolation Transformer (1000VA).
Ground Bond Testing to 30A AC with Adjustable Limit.
Line Leakage Current Measurement (Earth, Patient and Enclosure) with 5 Human Body Models.
Monitoring of DUT Current Draw.
Programmable Ramp and Test Times.
Storage of 99 Tests Setups with 99 Steps per Setup.
Continuous Leakage Current Monitoring.
Trip Current Programmable to 40mA AC and 20mA DC.
Front Panel Lockout via Password.
Standard IEEE and Remote Control Interfaces.
Optional RS232 Interface.
Insulation Resistance Measurements from 100kO to 50GO.
QuadTech Guardian6100 Production Safety Analyzer(CE, TUV)
Programmable output voltage to 5kV AC and 6kV DC.
Ground Bond Testing to 30A AC with Adjustable Limit.
Line Leakage Current Measurement (Earth, Patient and Enclosure) with 5 Human Body Models.
Monitoring of DUT Current Draw.
Programmable Ramp and Test Times.
Storage of 99 Tests Setups with 99 Steps per Setup.
Continuous Leakage Current Monitoring.
Trip Current Programmable to 40mA AC and 20mA DC.
Front Panel Lockout via Password.
Standard IEEE and Remote Control Interfaces.
Optional RS232 Interface.
Insulation Resistance Measurements from 100kO to 50GO.
QuadTech Guardian6200 Production Safety Analyzer(CE, TUV)
Programmable Output Voltage to 5kV AC and 6kV DC.
Ground Bond Testing to 30A AC with Adjustable Limit.
Monitoring of DUT Current Draw.
Monitoring of DUT Power Consumption.
Line/Earth Leakage Current Measurement (UL1563/UL1950) with 5 Human Body Models.
Insulation Resistance Measurements from 100kO. to 50GO.
Programmable Ramp and Test Times.
Storage of 99 Tests Setups with 99 Steps per Setup.
Continuous Leakage Current Monitoring.
Trip Current Programmable to 40mA AC and 20mA DC.
Front Panel Lockout via Password.
Standard IEEE and Remote Control Interfaces.
Optional RS232 Interface.
QuadTech Sentry10/50Plus Hipot/Ground bond Tester
Combines the features of the Sentry 10 Plus and 50 Plus.
Includes:
G13 Corded Product Adapter(115V).
S12 Load Box, resistive.
S15 Interconnection Cable to S50.
QuadTech Sentry10Plus AC Hipot Tester (CE, TUV)
Upgradable: Add DC and or IR.
Cost Effective Solution for Hipot.
Programmable Output Voltage to 5KV AC.
Programmable Ramp, Test and Fall Times.
Leakage Current 20ma AC.
Storage/Recall: 60 Tests.
Ground Fault Interrupt (GFI).
Fast Discharge of DUT and Fast HV Output Cutoff.
EN 50191 3ma Current Limit.
Pause Mode.
Remote IO Interface.
Large Enhanced Graphical Display.
Front and Rear Output Connectors.
QuadTech Sentry20Plus AC/DC Hipot Tester (CE, TUV)
Upgradable: Add IR.Cost Effective Solution for Hipot.
Programmable Output Voltage to 5KV AC and 6KV DC.
Programmable Ramp, Test and Fall Times.
Leakage Current 20ma AC, 5ma DC.
Storage/Recall: 60 Tests.
Ground Fault Interrupt (GFI).
Fast Discharge of DUT and Fast HV Output Cutoff.
Monitor DC In-Rush Current.
EN 50191 3ma Current Limit.
Pause Mode.
Remote IO Interface.
Large Enhanced Graphical Display.
Front and Rear Output Connectors.
QuadTech Sentry30Plus AC/DC/IR Hipot Tester (CE, TUV )
Cost Effective Solution for Hipot.
Programmable Output Voltage to 5KV AC and 6KV DC.
Programmable Ramp, Test and Fall Times.
Leakage Current 20ma AC, 5ma DC.
Resistance Measurements from .1M Ohm to 50G Ohm.
Storage/Recall: 60 Tests.
Ground Fault Interrupt (GFI).
Fast Discharge of DUT and Fast HV Output Cutoff.
Monitor DC In-Rush Current.
EN 50191 3ma Current Limit.
Pause Mode.
Remote IO Interface.
Large Enhanced Graphical Display.
Front and Rear Output Connectors.
QuadTech Sentry50Plus Ground Bond Tester
Programmable Output Current from 3A to 30A AC.
Programmable Source Voltage from 1.0 to 8.0V rms.
Resistance Measurements from 0.1mO to 510mO.
Programmable High and Low Limits.
Programmable Test Time.
Storage of 99 Tests Setups with Multiple Steps per Measurement.
Remote I/O Interface.
Graphic LCD.
Front Panel Lockout.
4-Terminal Kelvin Connection.
Built-in Calibration Software.
Compatible with Sentry & Guardian Series Hipot Testers.
Rod-L M100DC Hipot Tester
Performs DC insulation breakdown and concurrent AC ground continuity tests. Output test vol: up to 5500V (DC); Output current: 5mA (standard), 10mA maximum Voltage ramp: 50V/sec. to 5000V/sec
Rod-L M25 Ground Continuity Tester
Performs ground continuity tests in full compliance with BSI VDE, and IEC; measures AC resistance from chassis of device under test (DUT) to power cord ground lead-0 to 0.15O, AC power source supplies: M25-25 Amps; M30-30 Amps; M35-35 Amps.
Tektronix P5120 Passive Probe
PROBE, PASSIVE; 200 MHZ, 20X , 1000 VRMS or 600VRMS CAT III,MAXIMUM INPUT VOLTAGE PROBE TIP to EARTH GROUND (600 VRMS CAT II,or 300 VRMS CAT III,MAXIMUM VOLTAGE BETWEEN the COMMON LEAD and EARTH GROUND FOR USE WITH TPS2000 SERIES)